Biomechanical evaluation of a biomimetic spinal construct

Overview of attention for article published in Journal of Experimental Orthopaedics, June 2014
Altmetric Badge

Citations

dimensions_citation
19 Dimensions

Readers on

mendeley
51 Mendeley
Title
Biomechanical evaluation of a biomimetic spinal construct
Published in
Journal of Experimental Orthopaedics, June 2014
DOI 10.1186/s40634-014-0003-z
Pubmed ID
Authors

Tian Wang, Jonathon R Ball, Mattew H Pelletier, William R Walsh

Abstract

Laboratory spinal biomechanical tests using human cadaveric or animal spines have limitations in terms of disease transmission, high sample variability, decay and fatigue during extended testing protocols. Therefore, a synthetic biomimetic spine model may be an acceptable substitute. The goal of current study is to evaluate the properties of a synthetic biomimetic spine model; also to assess the mechanical performance of lateral plating following lateral interbody fusion. Three L3/4 synthetic spinal motion segments were examined using a validated pure moment testing system. Moments (±7.5 Nm) were applied in flexion-extension (FE), lateral bending (LB) and axial rotation (AR) at 1Hz for total 10000 cycles in MTS Bionix. An additional test was performed 12 hours after 10000 cycles. A ±10 Nm cycle was also performed to allow provide comparison to the literature. For implantation evaluation, each model was tested in the 4 following conditions: 1) intact, 2) lateral cage alone, 3) lateral cage and plate 4) anterior cage and plate. Results were analysed using ANOVA with post-hoc Tukey's HSD test. Range of motion (ROM) exhibited logarithmic growth with cycle number (increases of 16%, 37.5% and 24.3% in AR, FE and LB respectively). No signification difference (p > 0.1) was detected between 4 cycles, 10000 cycles and 12 hour rest stages. All measured parameters were comparable to that of reported cadaveric values. The ROM for a lateral cage and plate construct was not significantly different to the anterior lumbar interbody construct for FE (p = 1.00), LB (p = 0.995) and AR (p = 0.837). Based on anatomical and biomechanical similarities, the synthetic spine tested here provides a reasonable model to represent the human lumbar spine. Repeated testing did not dramatically alter biomechanics which may allow non-destructive testing between many different procedures and devices without the worry of carry over effects. Small intra-specimen variability and lack of biohazard makes this an attractive alternative for in vitro spine biomechanical testing. It also proved an acceptable surrogate for biomechanical testing, confirming that a lateral lumbar interbody cage and plate construct reduces ROM to a similar degree as anterior lumbar interbody cage and plate constructs.

Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 51 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 51 100%

Demographic breakdown

Readers by professional status Count As %
Other 10 20%
Student > Ph. D. Student 8 16%
Researcher 6 12%
Student > Master 6 12%
Student > Bachelor 3 6%
Other 7 14%
Unknown 11 22%
Readers by discipline Count As %
Engineering 16 31%
Medicine and Dentistry 13 25%
Mathematics 1 2%
Nursing and Health Professions 1 2%
Biochemistry, Genetics and Molecular Biology 1 2%
Other 4 8%
Unknown 15 29%