Title |
Automatic extraction of forward stroke volume using dynamic PET/CT: a dual-tracer and dual-scanner validation in patients with heart valve disease
|
---|---|
Published in |
EJNMMI Physics, October 2015
|
DOI | 10.1186/s40658-015-0133-0 |
Pubmed ID | |
Authors |
Hendrik Johannes Harms, Lars Poulsen Tolbod, Nils Henrik Stubkjær Hansson, Tanja Kero, Lovisa Holm Orndahl, Won Yong Kim, Tomas Bjerner, Kirsten Bouchelouche, Henrik Wiggers, Jørgen Frøkiær, Jens Sörensen |
Abstract |
The aim of this study was to develop and validate an automated method for extracting forward stroke volume (FSV) using indicator dilution theory directly from dynamic positron emission tomography (PET) studies for two different tracers and scanners. 35 subjects underwent a dynamic (11)C-acetate PET scan on a Siemens Biograph TruePoint-64 PET/CT (scanner I). In addition, 10 subjects underwent both dynamic (15)O-water PET and (11)C-acetate PET scans on a GE Discovery-ST PET/CT (scanner II). The left ventricular (LV)-aortic time-activity curve (TAC) was extracted automatically from PET data using cluster analysis. The first-pass peak was isolated by automatic extrapolation of the downslope of the TAC. FSV was calculated as the injected dose divided by the product of heart rate and the area under the curve of the first-pass peak. Gold standard FSV was measured using phase-contrast cardiovascular magnetic resonance (CMR). FSVPET correlated highly with FSVCMR (r = 0.87, slope = 0.90 for scanner I, r = 0.87, slope = 1.65, and r = 0.85, slope = 1.69 for scanner II for (15)O-water and (11)C-acetate, respectively) although a systematic bias was observed for both scanners (p < 0.001 for all). FSV based on (11)C-acetate and (15)O-water correlated highly (r = 0.99, slope = 1.03) with no significant difference between FSV estimates (p = 0.14). FSV can be obtained automatically using dynamic PET/CT and cluster analysis. Results are almost identical for (11)C-acetate and (15)O-water. A scanner-dependent bias was observed, and a scanner calibration factor is required for multi-scanner studies. Generalization of the method to other tracers and scanners requires further validation. |
X Demographics
Geographical breakdown
Country | Count | As % |
---|---|---|
Unknown | 2 | 100% |
Demographic breakdown
Type | Count | As % |
---|---|---|
Members of the public | 2 | 100% |
Mendeley readers
Geographical breakdown
Country | Count | As % |
---|---|---|
Unknown | 23 | 100% |
Demographic breakdown
Readers by professional status | Count | As % |
---|---|---|
Student > Master | 3 | 13% |
Researcher | 3 | 13% |
Student > Bachelor | 1 | 4% |
Lecturer | 1 | 4% |
Professor > Associate Professor | 1 | 4% |
Other | 0 | 0% |
Unknown | 14 | 61% |
Readers by discipline | Count | As % |
---|---|---|
Medicine and Dentistry | 5 | 22% |
Nursing and Health Professions | 2 | 9% |
Biochemistry, Genetics and Molecular Biology | 1 | 4% |
Earth and Planetary Sciences | 1 | 4% |
Computer Science | 1 | 4% |
Other | 0 | 0% |
Unknown | 13 | 57% |