Method dependence, observer variability and kidney volumes in radiation dosimetry of 177Lu-DOTATATE therapy in patients with neuroendocrine tumours

Overview of attention for article published in EJNMMI Physics, October 2015
Altmetric Badge

Citations

dimensions_citation
40 Dimensions

Readers on

mendeley
34 Mendeley
Title
Method dependence, observer variability and kidney volumes in radiation dosimetry of 177Lu-DOTATATE therapy in patients with neuroendocrine tumours
Published in
EJNMMI Physics, October 2015
DOI 10.1186/s40658-015-0127-y
Pubmed ID
Authors

Mattias Sandström, Ezgi Ilan, Anna Karlberg, Silvia Johansson, Nanette Freedman, Ulrike Garske-Román

Abstract

Radionuclide therapy can be individualized by performing dosimetry. To determine absorbed organ doses in (177)Lu-DOTATATE therapy, three methods based on activity concentrations are currently in use: the small volume of interest (sVOI) method, and two methods based on large VOIs either on anatomical CT (aVOI) or on thresholds on functional images (tVOI). The main aim of the present work was to validate the sVOI in comparison to the other two methods regarding agreement and time efficiency. Secondary aims were to investigate inter-observer variability for the sVOI and the change of functional organ volumes following therapy. Thirty patients diagnosed with neuroendocrine tumours undergoing therapy with (177)Lu-DOTATATE were included. Each patient underwent three SPECT/CT scans at 1, 4 and 7 days after the treatment. Three independent observers calculated absorbed doses to the right and left kidney and the spleen using sVOI and one observer used aVOI. For tVOI, the absorbed doses were calculated based on automatically drawn isocontours around the organs at different thresholds (42, 50, 60 and 70 %). The inter-observer difference between the calculated absorbed doses for sVOI was calculated, and the differences between the three methods were computed. Ratios of organ volumes acquired at days 1, 4 and 7 versus the volume at day 1 were calculated for the tVOI method. The differences in results of the absorbed dose calculations using all the sVOI and tVOI were small (<5 %). Absorbed dose calculations using aVOI differed slightly more from these results but were still below 10 %. The differences between the three dose calculation methods varied between <5 and 10 %. The organ volumes derived from the tVOI were independent of time for the spleen while they decreased with time for the kidneys. The fastest analysis was performed with the sVOI method. All three dose calculation methods rendered comparable results with small inter-observer differences for sVOI. Unlike the spleen, the functional volume of the kidneys decreased over time during therapy, which suggests that the absorbed dose calculation for the kidneys on activity concentrations should be performed for each time point. The sVOI is the preferred method for calculating absorbed doses in solid organs.

Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 34 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 34 100%

Demographic breakdown

Readers by professional status Count As %
Researcher 7 21%
Student > Ph. D. Student 6 18%
Student > Master 6 18%
Student > Postgraduate 2 6%
Other 2 6%
Other 6 18%
Unknown 5 15%
Readers by discipline Count As %
Physics and Astronomy 10 29%
Medicine and Dentistry 9 26%
Nursing and Health Professions 2 6%
Pharmacology, Toxicology and Pharmaceutical Science 1 3%
Mathematics 1 3%
Other 4 12%