Development and validation of an HPLC method for the determination of vancomycin in human plasma and its comparison with an immunoassay (PETINIA)

Overview of attention for article published in SpringerPlus, February 2016
Altmetric Badge

Citations

dimensions_citation
41 Dimensions

Readers on

mendeley
76 Mendeley
Title
Development and validation of an HPLC method for the determination of vancomycin in human plasma and its comparison with an immunoassay (PETINIA)
Published in
SpringerPlus, February 2016
DOI 10.1186/s40064-016-1778-4
Pubmed ID
Authors

Muhammad Usman, Georg Hempel

Abstract

Vancomycin (VAN) is among those antibiotics for which therapeutic drug monitoring is highly recommended. For this purpose a reliable method with small sample volume was required for quantification of VAN in human plasma. Therefore, a selective and sensitive method of high performance liquid chromatography was developed and validated. The separation was carried out isocratically by using a mobile phase NH4H2PO4 (50 mM, pH 2.2)-acetonitrile (88:12, v/v) at a flow rate of 0.36 mL/min on a nucleodur C18 column (125 mm × 4.6 mm, 5 µm) with UV detection at 205 nm. Sample preparation was done by deproteination of plasma with 70 % perchloric acid and a liquid/liquid extraction. Validation was performed according to the European Medicines Agency guideline. The method showed linearity over the range of 0.25-60 mg/L with a coefficient of determination r(2) ≥ 0.999 and a lower limit of quantification of 0.25 mg/L. No interference was observed in blank plasma samples at the retention time of VAN. The percentage relative recovery and coefficient of variation (CV%) values for accuracy and precision were within the acceptable limits. Stability was proved at room temperature for 24 h, after repeated freeze and thaw cycles and storage at -20 °C for 3 months. A good correlation was observed (r = 0.947) by comparing with the results of an immunoassay (PETINIA, Siemens) in 289 samples. In conclusion the method proved simple, sensitive and cost effective for quantification of VAN in human plasma.

Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 76 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 76 100%

Demographic breakdown

Readers by professional status Count As %
Student > Ph. D. Student 11 14%
Student > Bachelor 11 14%
Student > Master 9 12%
Student > Doctoral Student 7 9%
Student > Postgraduate 5 7%
Other 16 21%
Unknown 17 22%
Readers by discipline Count As %
Pharmacology, Toxicology and Pharmaceutical Science 22 29%
Chemistry 12 16%
Medicine and Dentistry 7 9%
Agricultural and Biological Sciences 6 8%
Biochemistry, Genetics and Molecular Biology 3 4%
Other 9 12%
Unknown 17 22%