Tendon end separation with loading in an Achilles tendon repair model: comparison of non-absorbable vs. absorbable sutures

Overview of attention for article published in Journal of Experimental Orthopaedics, July 2017
Altmetric Badge

Mentioned by

twitter
1 tweeter

Citations

dimensions_citation
2 Dimensions

Readers on

mendeley
15 Mendeley
Title
Tendon end separation with loading in an Achilles tendon repair model: comparison of non-absorbable vs. absorbable sutures
Published in
Journal of Experimental Orthopaedics, July 2017
DOI 10.1186/s40634-017-0101-9
Pubmed ID
Authors

Michael R. Carmont, Jan Herman Kuiper, Karin Grävare Silbernagel, Jón Karlsson, Katarina Nilsson-Helander

Abstract

Rupture of the Achilles tendon often leads to long-term morbidity, particularly calf weakness associated with tendon elongation. Operative repair of Achilles tendon ruptures leads to reduced tendon elongation. Tendon lengthening is a key problem in the restoration of function following Achilles tendon rupture. A study was performed to determine differences in initial separation, strength and failure characteristics of differing sutures and numbers of core strands in a percutaneous Achilles tendon repair model in response to initial loading. Nineteen bovine Achilles tendons were repaired using a percutaneous/minimally invasive technique with a combination of a modified Bunnell suture proximally and a Kessler suture distally, using non-absorbable 4-strand 6-strand repairs and absorbable 8-strand sutures. Specimens were then cyclically loaded using phases of 10 cycles of 100 N, 100 cycles of 100 N, 100 cycles of 190 N consistent with early range of motion training and weight-bearing, before being loaded to failure. Pre-conditioning of 10 cycles of 100 N resulted in separations of 4 mm for 6-strand, 5.9 mm for 4-strand, but 11.5 mm in 8-strand repairs, this comprised 48.5, 68.6 and 72.7% of the separation that occurred after 100 cycles of 100 N. The tendon separation after the third phase of 100 cycles of 190 N was 17.4 mm for 4-strand repairs, 16.6 mm for 6-strand repairs and 26.6 mm for 8-strand repairs. There were significant differences between the groups (p < 0.0001). Four and six strand non-absorbable repairs had significantly less separation than 8-strand absorbable repairs (p = 0.017 and p = 0.04 respectively). The mean (SEM) ultimate tensile strengths were 4-strand 464.8 N (27.4), 6-strand 543.5 N (49.6) and 8-strand 422.1 N (80.5). Regression analysis reveals no significant difference between the overall strength of the 3 repair models (p = 0.32) (4 vs. 6: p = 0.30, 4 vs. 8: p = 0.87; 6 vs. 8: p = 0.39). The most common mode of failure was pull out of the Kessler suture from the distal stump in 41.7% of specimens. The use of a non-absorbable suture resulted in less end-to-end separation when compared to absorbable sutures when an Achilles tendon repair model was subject to cyclical loading. Ultimate failure occurred more commonly at the distal Kessler suture end although this occurred with separations in excess of clinical failure. The effect of early movement and loading on the Achilles tendon is not fully understood and requires more research.

Twitter Demographics

The data shown below were collected from the profile of 1 tweeter who shared this research output. Click here to find out more about how the information was compiled.

Mendeley readers

The data shown below were compiled from readership statistics for 15 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 15 100%

Demographic breakdown

Readers by professional status Count As %
Student > Ph. D. Student 5 33%
Student > Master 2 13%
Researcher 2 13%
Student > Doctoral Student 2 13%
Student > Postgraduate 2 13%
Other 2 13%
Readers by discipline Count As %
Medicine and Dentistry 5 33%
Nursing and Health Professions 3 20%
Agricultural and Biological Sciences 2 13%
Engineering 2 13%
Unspecified 2 13%
Other 1 7%

Attention Score in Context

This research output has an Altmetric Attention Score of 1. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 25 July 2017.
All research outputs
#10,218,212
of 11,516,709 outputs
Outputs from Journal of Experimental Orthopaedics
#34
of 43 outputs
Outputs of similar age
#221,726
of 262,835 outputs
Outputs of similar age from Journal of Experimental Orthopaedics
#1
of 1 outputs
Altmetric has tracked 11,516,709 research outputs across all sources so far. This one is in the 1st percentile – i.e., 1% of other outputs scored the same or lower than it.
So far Altmetric has tracked 43 research outputs from this source. They receive a mean Attention Score of 4.1. This one scored the same or higher as 9 of them.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 262,835 tracked outputs that were published within six weeks on either side of this one in any source. This one is in the 1st percentile – i.e., 1% of its contemporaries scored the same or lower than it.
We're also able to compare this research output to 1 others from the same source and published within six weeks on either side of this one. This one has scored higher than all of them