↓ Skip to main content

Extracorporeal CO2 removal by hemodialysis: in vitro model and feasibility

Overview of attention for article published in Intensive Care Medicine Experimental, April 2017
Altmetric Badge

About this Attention Score

  • In the top 25% of all research outputs scored by Altmetric
  • Good Attention Score compared to outputs of the same age (78th percentile)
  • High Attention Score compared to outputs of the same age and source (99th percentile)

Mentioned by

twitter
11 X users
patent
1 patent

Citations

dimensions_citation
33 Dimensions

Readers on

mendeley
51 Mendeley
Title
Extracorporeal CO2 removal by hemodialysis: in vitro model and feasibility
Published in
Intensive Care Medicine Experimental, April 2017
DOI 10.1186/s40635-017-0132-7
Pubmed ID
Authors

Alexandra G. May, Ayan Sen, Matthew E. Cove, John A. Kellum, William J. Federspiel

Abstract

Critically ill patients with acute respiratory distress syndrome and acute exacerbations of chronic obstructive pulmonary disease often develop hypercapnia and require mechanical ventilation. Extracorporeal carbon dioxide removal can manage hypercarbia by removing carbon dioxide directly from the bloodstream. Respiratory hemodialysis uses traditional hemodialysis to remove CO2 from the blood, mainly as bicarbonate. In this study, Stewart's approach to acid-base chemistry was used to create a dialysate that would maintain blood pH while removing CO2 as well as determine the blood and dialysate flow rates necessary to remove clinically relevant CO2 volumes. Bench studies were performed using a scaled down respiratory hemodialyzer in bovine or porcine blood. The scaling factor for the bench top experiments was 22.5. In vitro dialysate flow rates ranged from 2.2 to 24 mL/min (49.5-540 mL/min scaled up) and blood flow rates were set at 11 and 18.7 mL/min (248-421 mL/min scaled up). Blood inlet CO2 concentrations were set at 50 and 100 mmHg. Results are reported as scaled up values. The CO2 removal rate was highest at intermittent hemodialysis blood and dialysate flow rates. At an inlet pCO2 of 50 mmHg, the CO2 removal rate increased from 62.6 ± 4.8 to 77.7 ± 3 mL/min when the blood flow rate increased from 248 to 421 mL/min. At an inlet pCO2 of 100 mmHg, the device was able to remove up to 117.8 ± 3.8 mL/min of CO2. None of the test conditions caused the blood pH to decrease, and increases were ≤0.08. When the bench top data is scaled up, the system removes a therapeutic amount of CO2 standard intermittent hemodialysis flow rates. The zero bicarbonate dialysate did not cause acidosis in the post-dialyzer blood. These results demonstrate that, with further development, respiratory hemodialysis can be a minimally invasive extracorporeal carbon dioxide removal treatment option.

X Demographics

X Demographics

The data shown below were collected from the profiles of 11 X users who shared this research output. Click here to find out more about how the information was compiled.
Mendeley readers

Mendeley readers

The data shown below were compiled from readership statistics for 51 Mendeley readers of this research output. Click here to see the associated Mendeley record.

Geographical breakdown

Country Count As %
Unknown 51 100%

Demographic breakdown

Readers by professional status Count As %
Researcher 10 20%
Student > Ph. D. Student 5 10%
Student > Master 5 10%
Student > Bachelor 4 8%
Other 4 8%
Other 7 14%
Unknown 16 31%
Readers by discipline Count As %
Medicine and Dentistry 20 39%
Chemical Engineering 3 6%
Engineering 2 4%
Biochemistry, Genetics and Molecular Biology 1 2%
Business, Management and Accounting 1 2%
Other 4 8%
Unknown 20 39%
Attention Score in Context

Attention Score in Context

This research output has an Altmetric Attention Score of 9. This is our high-level measure of the quality and quantity of online attention that it has received. This Attention Score, as well as the ranking and number of research outputs shown below, was calculated when the research output was last mentioned on 23 January 2020.
All research outputs
#4,218,889
of 25,498,750 outputs
Outputs from Intensive Care Medicine Experimental
#125
of 540 outputs
Outputs of similar age
#69,886
of 324,969 outputs
Outputs of similar age from Intensive Care Medicine Experimental
#1
of 9 outputs
Altmetric has tracked 25,498,750 research outputs across all sources so far. Compared to these this one has done well and is in the 83rd percentile: it's in the top 25% of all research outputs ever tracked by Altmetric.
So far Altmetric has tracked 540 research outputs from this source. They typically receive more attention than average, with a mean Attention Score of 7.9. This one has done well, scoring higher than 76% of its peers.
Older research outputs will score higher simply because they've had more time to accumulate mentions. To account for age we can compare this Altmetric Attention Score to the 324,969 tracked outputs that were published within six weeks on either side of this one in any source. This one has done well, scoring higher than 78% of its contemporaries.
We're also able to compare this research output to 9 others from the same source and published within six weeks on either side of this one. This one has scored higher than all of them